For the HLS-II bunch current measurement system, in order to obtain the absolute value of bunch current, the calibration factor should be determined by using DCCT. At the HLS storage ring, the stretch effect of bunch length is observed and the change rate is about 19% when the bunch current decays over time and this will affect the performance of bunch current detection. To overcome the bunch stretch influence in the HLS-II bunch current measurement, an evaluation about pickup type and signal processing is carried out. Strip-line pickup and button pickup are selectable, and the theoretical analysis and demonstration experiment are performed to find out an acceptable solution for the bunch current measurement system at HLS-H. The experimental data analysis shows that the normalized calibration factor will change by about 27% when the bunch length changes by about 19% if using the button pickup and processing by peak value of bunch signal; the influence will be reduced to 2% less if adopting the strip-line pickup and integral.
The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.
Central RF frequency is a key parameter of storage rings. This paper presents the measurement of central RF frequency of the HLS-Ⅱ storage ring with the sextupole modulation method. Firstly, the basis of central RF frequency measurement of the electron storage ring is briefly introduced. Then, the error sources and the optimized measurement method for the HLS-Ⅱ storage ring are discussed. The workflow of a self-compiled Matlab script used in central RF frequency measurement is also described. Finally, the results achieved by using two data processing methods to cross-check each other are shown. The measured value of the central RF frequency demonstrates that the circumference deviation of the HLS-Ⅱ storage ring is less than 1 mm.
An interferometer system and an imaging system using visible synchrotron radiation(SR) have been installed in the Hefei Light Source(HLS) II storage ring. Simulations of these two systems are given using Synchrotron Radiation Workshop(SRW) code. With these two systems, the beam energy spread and the beam emittance can be measured. A detailed description of these two systems and the measurement method is given in this paper. The measurement results of beam size, emittance and energy spread are given at the end.